| Flow Range: | up to 2300 GPM (530 m³/hr) |
| Process temperature: | up to 750°F (400°C) |
| Line size: | ¼”-10″ (8-250mm) |
| Operating pressure: | up to 870 psig (60 barg) |
| Accuracy: | ±0.5% (Std), ±0.2% (Opt) of reading |
| Body Material: | CS (Std), 304SS or 316SS (Opt) |
| Repeatability: | ±0.03% of reading |
| Enclosure Rating: | NEMA 4X (IP 65) |
| Viscosity: | up to 1,000 cP |
| Display: | rate, total, low flow cut-off, battery consumption |
| Housing Protection: | IP65; IP67; IP68 |
| Frequency Range: | 1 up to 30,000 Hz |
| Ambient temperature: | -22 to 158°F (-30 to +70°C) |
| Working Humidity: | < 90% @ 75°F |
| Supply Voltage UB: | +24VDC, regulated |
| Ex-protection: | II 2 G Eex ia IIC T4, BVS 03 ATEX E 205 |
| User Parameters: | K-factors, linear correction coefficeint, flowrate input signal section points, temperature |
| Housing: | IP 68, aluminum AlMgSiPb, blue anodized |
| Output: | pulse, 4-20 mA or RS485 |