The helical rotors’ motion is transmitted to the display via a sealed coupling & drive system that enables the display to provide accurate data for both flow rate and total accumulated flow.
The unique helical rotor design provides a number of advantages over traditional gear-type PD meters including reduced pressure drop, the virtual elimination of down-stream pulsations, enhanced particle tolerance, and reduced maintenance. The advantages provided by the helical rotor make the ALBRPD an ideal choice for many applications including oil-in-water media and fluids with small ammounts of entrained solids.

| Flow Range: | up to 8800 GPM (2000 m³/hr) |
| Process temperature: | -22 ~ 480°F (-30 ~ 250°C) |
| Line size: | ¼”-16″ (8-400mm) ANSI or DIN Flange |
| Operating pressure: | max. 930 psig (64bar) |
| Accuracy: | ±0.1% |
| Body Material: | Stainless Steel 304 and Carbon Steel |
| Repeatability: | ±0.01% |
| Enclosure Rating: | NEMA 4 (IP 65) |
| Viscosity: | 0~20,000 cP |
| Working Temperature: | 104 ~ 176°F (40 ~ 80°C) |
| Display: | rate, total, low flow cust-off, battery consumption |
| Working Humidity: | < 90% @ 75°F |
| Current Output: | 4-20mA, (two wire system w/ 600Ω max loop load) |
| Digital Output: | RS485/RS232 communication with Modbus RTU (powered by 24VDC±5% and <60mA) |
| User Parameters: | K-factors, linear correction coefficeient, flowrate input signal section points, temperature and pressure compensation, set pulse output range, decimal adjustment, ect. |
| Communciation Baud Rates: | User selectable (1200, 2400, 4800 or 9600) |
| Pulse Output: | (24VDC±5%, VH≥20V,) VL<1V and output load < 200Ω) |